 CORCOM Product Guide Multi-Function Power Entry Modules with RFI Power Line Filters
LA Series
UL Recognized CSA Certified VDE Approved
FLA/XLA/ZLA
LA Series
The LA series is a multi-function power entry connector with a choice of filtering capabilities. The series features an IEC power line connector, selectable North American or dual European fusing capabilities, DPST on/off switch, and 120/240 voltage selection. The filtered LA units provide a one piece solution to power entry needs and provide a filtering solution for almost any RFI problem. Their vertical design is flange mounted. This series offers three levels of filtering, all carrying UL recognition, CSA certification, and VDE approval. FLA Model - General purpose RFI filter designed for susceptibility applications, effectively providing RFI control of line-to-ground noise. XLA Model - High performance RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emissions limits. ZLA Model - Premium performance RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. Voltage Selection To change selected voltage: remove the fuse cartridge using a small blade screwdriver or similar tool; select the desired voltage by matching the arrow on the fuse cartridge to the arrow located on the front of the unit (lower right corner); replace the fuse cartridge making sure the voltage selection arrow aligns with the arrow located on the front of the unit. Fuse Changing Remove the fuse cartridge using a small blade screwdriver or similar tool; for European fusing pull out the sliding fuse covers located at the top of each fuse compartment; insert desired fuses; push the sliding fuse covers back in place and insert the fuse cartridge back into the unit making sure the voltage selection arrow aligns with the arrow located on the front of the unit. (Note: Single North American or European fuse placement is always on the side of the desired voltage selection arrow behind the fuse symbol; the other compartment may be used as a spare or be left blank. Dual European fusing capability is available for 220/240 volts only.) 122
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents.
Specifications
Maximum leakage current, each line-to-ground: @ 120 VAC 60 Hz: FLA Model 0.25 mA XLA/ZLA Models 0.30 mA @ 250 VAC 50 Hz: Hipot rating (one minute): line-to-ground line-to-line Operating voltages: Operating frequency: Rated voltage (max.): Switch: All Models 0.50 mA 1500 VAC 1450 VDC 110,120, 220/240 VAC 50/60 Hz 250 VAC Double-insulated, rated for 50,000 operations at full load. 35 Amp inrush capability Accepts one 1/4" x 1-1/4" fuse, or two 5 x 20 mm fuses .110 [2.79] terminals
Fuse (not included): Terminals:
Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Frequency-MHz Rating .01 .05 .15 .5 1 5 FLA 5A 14 21 26 40 XLA 3A 2 12 21 35 46 44 ZLA 3A 14 28 38 42 40 40 Line-to-line in 50 ohm circuit Current Rating XLA 3A ZLA 3A Frequency-MHz .02 .03 .05 .07 .15 .5 1 5 3 14 29 5 38 33 57
10 46 44 40
30 50 40 40
10
30 50 50
60 65 60 50 72 72 65 55
Dimensions are shown for reference purposes only. Specifications subject to change.
USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0
www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Multi-Function Power Entry Modules with RFI Power Line Filters (Continued)
LA Series
Case Style
FLA, XLA & ZLA
A F B
Case Dimensions
Part No. 5EFLA2S 3EXLA2S
C D
A (max) 1.99 50.5 1.99 50.5 1.99 50.5
B
0.15 0.381
C (max) 2.59 65.79 2.59 65.79 2.59 65.79
D E F (max) (max) (max) 2.41 61.21 2.41 61.21 2.41 61.21 3.16 1.18 68.07 29.97 4.16 1.18 105.7 29.97 4.16 1.18 105.7 29.97
3EZLA2S
1.57 39.9 1.57 39.9 1.57 39.9
Power Entry Modules
Typical dimensions: Terminals: .110 [4.80] Holes: .059 [1.5] Dia. Max., except solder lug ground tap with wire wrap. Mounting Holes: .142 [3.6] Dia. (2)
Electrical Schematics
FLA
Power on/off Neutral C Ground D E F Phase G Customer Transformer Primaries D ABC 120V D E F 240V A B A B A or D 120V
XLA & ZLA
On/Off Neutral
Hot
Note: Provision for dual European fusing by connection to "A". Resistor location for reference only.
Catalog 1654001 Revised 05-07
220-240 110-120
Recommended Panel Cutout
FL, XLA & ZLA
.093 R 2.36
E
.140 Dia. (2) 3.56
2.42* 61.47
1.19* 30.23 1.57 39.88
* +.020 - .00
+ 0.5 - .00
Note: All models allow front mounting only.
Part Numbers
0
120V
E F
5EFLA2S 3EXLA2S 3EZLA2S
ABC 120V D E F 240V A B C D E F G D E F 120V A B A or D 120V
Customer Transformer Primaries
123
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com


▲Up To Search▲   

 
Price & Availability of 3EZLA2S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X